Hydro-Seeder Procedures |
|
|
This pertains to all employee's and customers who will be using the
hydro-seeder. |
|
q |
Check all equipment and read all procedures before beginning !!!! |
|
Before Starting or restarting |
|
1 |
Check Oil Level to make
sure it is full! |
|
|
|
2 |
Check Throttle Control to
make sure it is at the low idle! See below |
|
3 |
Check Auger
level to make sure it is
in the neutral position! See below |
|
4 |
Check Pump Engagement level
to make sure it is in the off position! See
below |
|
Important: If the above instructions are not
followed Hydro-Seeder may not turn on!!! |
|
|
Starting Instructions |
|
|
1 |
Turn key to pre-heat position, left (L) |
|
2 |
Wait for glow plug light to go out. |
|
3 |
Hold down red push button. |
|
|
IMPORTANT: HOLD DOWN BUTTON FOR 10 SECONDS AFTER STARTING. |
|
4 |
Turn key to the right to start engine. |
|
5 |
After 10 seconds, stop holding red button. |
|
|
|
|
|
Throttle Control |
|
|
|
1 |
The throttle control is located on upper level of hydro- |
|
|
|
seeder next to the hose reel. |
|
2 |
To increase throttle, gently pull up on throttle. |
|
3 |
To decrease throttle, gently push down on throttle. |
|
|
|
|
|
Mixing Instructions |
|
|
|
1 |
Fill Tank 3/4 full of water |
|
|
2 |
Start machine |
|
3 |
Bring idle to 30% - 40% of maximum |
|
4 |
Set auger in the mix position |
|
5 |
Add all materials while mixing |
|
6 |
Top off with water |
|
7 |
Now you are ready to spray. |
|
|
|
|
|
|
|
|
|
|
|
|
Pump Control |
|
|
|
1 |
To engage pump, pull handle next to throttle towards |
|
|
|
back of hydro-seeder. |
|
2 |
To disengage pump, push handle towards front of |
|
|
hydro-seeder. |
|
|
|
|
|
IMPORTANT |
|
|
|
1 |
Do not engage pump until ready to spray. |
|
|
2 |
Do not open yellow valve until you have the hose |
|
|
pulled out and are ready to spray. |
|
|
Having the pump running and yellow valve on for to long without spraying
will clog the hose. |
|
|
Shut Off Procedures |
|
|
|
1 |
Disengage Pump! |
|
2 |
Disengage Auger! |
|
|
|
3 |
Lower Engine Throttle all the way to the lowest idle position! |
|
4 |
Allow Hydro-Seeder to run at this level for a couple minutes! |
|
5 |
Turn key to strait position. |
|
|
|
|
Cleaning Instructions |
|
|
|
1 |
Clean inside and outside of hydro-seeder when finished. |
|
2 |
Open Drain to dump water and excess material. |
|
|
|
3 |
Refill with Appox. 100 gal of water. |
|
|
|
4 |
Start and pump out hose and/or Turrot if used. |
|
|
|
5 |
Check to make sure you have all nozzles & adapters once finished. |
|
|